Building Inspection Procedures

ALL PERMITS FOR BUILDINGS, MECHANICALS, SEPTIC SYSTEMS, WELLS (WHEN REQUIRED)AND DRIVEWAYS MUST BE ISSUED PRIOR TO STARTING WORK.

NO INSPECTIONS WILL BE MADE UNTIL APPLICABLE PERMITS ARE IN.

No Building Permit Application will be accepted without the following:

  1. Zoning Approval
  2. Completed building application and fee.
  3. Complete building plan, two copies (approved copy will be returned).
  4. Proposed plot plan - certified plot plan when foundation poured.
  5. REScheck-Residential Energy Code Calculations (see Dept. of Energy website:www.energycodes.gov/rescheck
  6. Well permit or public water supply.
  7. Septic permit or sanitary sewer permit.

The following inspections are required after a building permit has been issued:

Type of InspectionTimingContact
Footing
 
Forms in place before pouringBuilding Inspector
(860) 379-8830
Walls, waterproofing, footing drains with insulation on foundation (if necessary).
 
Before backfillingBuilding Inspector
(860) 379-8830
Certified Plot Plan (as built)
 
Before any framingBuilding Inspector
(860) 379-8830
In-ground mechanicals
 
Before coveringBuilding Inspector
(860) 379-8830
Renovation/Remodel
 
Inspection Before Work BeginsBuilding Inspector
(860) 379-8830
Roofing
 
While in progress and as strippingBuilding Inspector
(860) 379-8830
Fireplaces
 
Throat height before tile and Smoke ChamberBuilding Inspector
(860) 379-8830

Rough Framing

 

Prior to any MechanicalsBuilding Inspector
(860) 379-8830

Rough Electric, Plumbing, Gas & Mechanicals

 

Prior to InsulationBuilding Inspector
(860) 379-8830
Basement floor
 
Before concrete is deliveredBuilding Inspector
(860) 379-8830
Insulation
 
Following installationBuilding Inspector
(860) 379-8830
Drywall
 
Before joint treatmentBuilding Inspector
(860) 379-8830
Septic SystemBefore coverFarmington Valley Health District
(860) 676-1953
(800) 909-3843
 
Sewer & Water connectionsBefore uncapping lateral and tapping main
 

Call Town Hall

860-379-3389

Water test and final approval of Septic SystemBefore Certificate of OccupancyFarmington Valley Health District
 
DrivewayBefore Certificate of OccupancyRoad Foreman
860-379-3389
 
Certificate of OccupancyFinal Inspection before OccupancyBuilding Inspector
(860) 379-8830